Dew Point Sensor FA 515 Ex

Introducing our new instrument for dew point or pressure dew point measurement in potentially explosive atmospheres – the FA 515 Ex. This device can be used in numerous non-aggressive gases.

Typical applications include Air/Compressed air, Argon, Nitrogen, Biogas, Natural gas, Hydrogen, and more.

Our dew point sensor, the FA 515 Ex, meets the following industry approval standards:

ATEX II 2G Ex ib IIC T4 Gb Zone 1, gas, intrinsically safe, Temp. 135°C

ATEX II 2D Ex ib IIIC T80°C Db Zone 21, dust, intrinsically safe, Temp. 80°C

Please note: The FA 515 Ex must be used only in conjunction with approved Ex-rated power supplies, safety barriers, or galvanic isolation devices, while ensuring the following maximum values:

Ui = 28 V max.

Ii = 95 mA max.

Pi = 0,65 W max.

TECHNICAL DATA FA 515 EX

 

Measuring range: -80…20 °Ctd = 4…20 mA
Pressure range: -1…500 bar
Power supply: 24 VDC (18…28 VDC)
Accuracy: ± 1 °C at -20…+20 °Ctd

± 2 °C at -50…-20 °Ctd

± 3 °C at -80…-50 °Ctd

Output: 4…20 mA in 2-wire technology
Protection class: IP 65
EMC: In acc. with DIN EN 61326-1
Operating temperature: -20…+70 °C
Storage temperature:

 

-40…+80 °C
Burden for analogue

output:

< 500 Ω at 24 V
Screw-in thread: G 1/2″ stainless steel

optional 5/8″ UNF

Connection: M12, 4-pin
Sensor protection: Sinter fi lter 50 µm stainless steel

 

Scroll to Top