TECHNICAL DATA FA 515 EX
Measuring range: | -80…20 °Ctd = 4…20 mA |
Pressure range: | -1…500 bar |
Power supply: | 24 VDC (18…28 VDC) |
Accuracy: | ± 1 °C at -20…+20 °Ctd
± 2 °C at -50…-20 °Ctd ± 3 °C at -80…-50 °Ctd |
Output: | 4…20 mA in 2-wire technology |
Protection class: | IP 65 |
EMC: | In acc. with DIN EN 61326-1 |
Operating temperature: | -20…+70 °C |
Storage temperature:
|
-40…+80 °C |
Burden for analogue
output: |
< 500 Ω at 24 V |
Screw-in thread: | G 1/2″ stainless steel
optional 5/8″ UNF |
Connection: | M12, 4-pin |
Sensor protection: | Sinter fi lter 50 µm stainless steel |