TECHNICAL DATA VA 409
Response area detection of direction: | < 0.1 m/s relative to 20 °C and 1000 mbar |
Measuring principle: | Calorimetric measurement |
Sensor: | Pt 30/ Pt 700/ Pt 330 |
Measured medium: | Air, gases |
Operating temperature: | 0…50 °C sensor tube -20…70 °C housing |
Operating pressure: | up to 16 bar |
Power supply: | 24 VDC, 40 mA |
Current consumption: | Max. 80 mA to 24 VDC |
Protection class: | IP 54 |
EMC: | in acc. with DIN EN 61326 |
Connection: | 2 x M12, 5-pin, plug A and plug B |
2 potential-free contacts: | 2 x U max. 60 VDC, l max 0.5 A (normally closed); On request: Normally open |
Housing: | Polycarbonate |
Sensor tube: | Stainless steel, 1.4301, length 160 mm, Ø 10 mm, safety ring Ø 11.5 mm, longer sensors on request |
Mounting thread: | G 1/2″ |
Housing diameter: | 65 mm |
Direction indication: | 2 LED`S |